Decoding the Mystery: Your Ultimate Guide to Pool Pump Wiring Schematics
Understanding your pool pump's wiring can seem daunting, especially if you're not electrically inclined. A faulty connection can lead to a non-functional pump, wasted energy, or even worse, a safety hazard. This comprehensive guide will demystify pool pump wiring schematics, providing you with the knowledge and tools to troubleshoot problems and ensure your pool pump operates efficiently and safely. We'll cover everything from interpreting basic diagrams to understanding different wiring configurations and troubleshooting common issues. By the end, you'll be confident in your ability to navigate the world of pool pump wiring.
Understanding Basic Pool Pump Wiring Schematics
Before diving into specific diagrams, let's establish a foundation. Pool pump wiring schematics utilize standard electrical symbols to represent components. These symbols typically include:
Power Source: Represented by a circle with a "+" and "-" indicating positive and negative terminals.
Circuit Breaker/Fuse: Shown as a switch-like symbol, indicating the protective device in your circuit.
Motor: Depicted as a circle with windings inside, showing the pump's motor.
Capacitor: A parallel line symbol indicating the capacitor, crucial for starting the motor.
Timer/Switch: A symbol representing any switch controlling the pump's operation (e.g., a timer or a manual on/off switch).
Ground: Typically represented by a triangle or a ground symbol, ensuring safety.
Deciphering the Symbols: A Practical Example
A typical schematic might show the power source connected to a circuit breaker, then to the capacitor and subsequently to the motor's terminals. The ground wire will connect directly to the pump's chassis. Understanding these simple symbols is the key to interpreting any pool pump wiring diagram.
Common Pool Pump Wiring Configurations
Pool pump wiring can vary depending on the pump's voltage (110V or 220V) and the presence of additional features like timers or automatic controls. Let's examine some common configurations:
Single-Phase Wiring (110V/120V)
This is the most common setup for smaller pools. The schematic typically shows a single power source connected to the pump's terminals via the circuit breaker and the capacitor. The capacitor is essential to provide the initial surge of power needed for the motor to start.
Three-Phase Wiring (220V/240V)
Larger pools often use three-phase pumps, requiring a more complex wiring setup. This configuration involves three separate hot wires and a neutral, resulting in a more powerful motor. The schematic will reflect this with three lines connected to the motor's terminals.
Wiring with a Timer
Many pool pumps use timers to automate their operation. The schematic will include a timer symbol in the circuit, showing how the timer controls the power flow to the pump.
Troubleshooting Your Pool Pump Wiring Using the Schematic
Your wiring schematic is your best friend when troubleshooting problems. If your pump isn't working, consult the diagram to:
Check for loose connections: Examine all connections for any looseness or corrosion.
Test the circuit breaker/fuse: Ensure the breaker hasn't tripped or the fuse hasn't blown.
Inspect the capacitor: A faulty capacitor can prevent the motor from starting. (Note: Capacitors store a charge even when disconnected; exercise caution when handling them.)
Verify voltage: Use a multimeter to check the voltage at the pump's terminals.
Safety Precautions When Working with Pool Pump Wiring
Always remember that working with electricity can be dangerous. Before attempting any wiring work:
Turn off the power: Always disconnect the power to the pump at the circuit breaker before working on the wiring.
Use appropriate tools: Employ insulated tools to prevent electrical shocks.
Consult a professional: If you are unsure about any aspect of the wiring, consult a qualified electrician. Improper wiring can lead to serious hazards.
Conclusion
Understanding your pool pump's wiring schematic is crucial for efficient operation and safety. By familiarizing yourself with the basic symbols, common configurations, and troubleshooting techniques, you'll be better equipped to maintain your pool pump and avoid costly repairs or potential hazards. Remember, safety should always be your top priority. If you are uncomfortable working with electricity, don't hesitate to call a qualified professional.
FAQs
Q1: Where can I find my pool pump's wiring schematic?
A1: The schematic is usually found on a sticker attached to the pump itself or in the owner's manual.
Q2: Can I use a different capacitor than the one specified in the schematic?
A2: No, using an incorrect capacitor can damage your pump motor. Always use the capacitor specified by the manufacturer.
Q3: My pool pump makes a buzzing sound but doesn't start. What could be the problem?
A3: This often indicates a problem with the capacitor. It might be faulty or have insufficient capacitance.
Q4: What should I do if I find a damaged wire?
A4: Replace the damaged wire with a wire of the same gauge and type. Ensure all connections are secure and properly insulated.
Q5: How often should I inspect my pool pump's wiring?
A5: It's good practice to inspect your pool pump's wiring at least once a year, or more frequently if you notice any unusual behavior or suspect a problem.
HAYWARD SELF-PRIMING SUPER PUMP INSTALLATION …
WINTERIZING/STORAGE. Drain pump by removing drain plug(s) and store in strainer basket. Disconnect electrical wires and pipe connections, and store pump in a dry, well-ventilated …
tm Wiring Diagram EXPLODED VIEW - ecopoolpumps.com
Wiring Diagram. WARNING: Before installing this instructions accompanying this pump. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. …
Mechanical Timing Controls For Two-Speed Pump …
Wiring a two-speed pump to an Intermatic mechanical timing control requires the use of both the T104M and the T106M. The T104M has a DPST (double pole, single throw) mechanical switch.
RX Clear ® Mighty Niagara In-ground pump
Install in-ground pool pump, wire motor in accordance with local and national electrical code requirements. Permently ground motor, by connecting ground wire to grounded bolt. Use size …
Wiring Diagram – Coverstar 220 Volt Hydraulic Automatic …
Apr 24, 2020 · Wire Terminal Locations on Back of Switch. After final wiring, if the cover movement doesn’t agree with the “Cover” – “Uncover” labels on the front of the switch, just …
Super Pump Series - Hayward
bonding wire to the pressure wire connector provided on the pump housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas …
A3101 E0301 A3100 - Wiring and Installation - Latham Pool
Additional Wiring Options: The 1601 electronic controller accepts several different directional inputs for motor control operation. Low Voltage (5VDC), and Low Voltage Touchpad (5VDC) …
Super II Pump - Hayward
All electrical wiring must be performed by qualified personnel, and must conform to local codes and regulations. Three Phase Motors are supplied with either six (6) or nine (9) motor leads …
ELECTRICAL WIRING INSTALLATION GUIDE - MY POOL …
This manual shows the electrical connection of your new pool step by step. The electrical connection must be made by an authorized electrician and ended with a revision.
Pool Pump Wiring Schematic Copy - netsec.csuci.edu
Understanding your pool pump's wiring schematic is crucial for efficient operation and safety. By familiarizing yourself with the basic symbols, common configurations, and troubleshooting …
Power-Flo LX / Power-Flo II Pump Series - Owner's Manual
The Power-Flo LXTM pump MUST be installed below the pool water line (see Figure to right). Self-priming Power-Flo IITM pumps may be installed up to four (4) feet above the pool water …
Hayward Super Pump™ Series - Owner's Manual - Pooltek
Super PumpTM Series. The Hayward Super PumpTM is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large …
Installation and Operation Manual - Nidec
Apr 16, 2020 · Wiring the Pool Pump Motor. The 1.65 THP pool pump motor is a Dual Voltage Model (115 or 230 Vac), while the 2.25 THP and 2.7 THP are Single Voltage Models (230 Vac …
Super Pump 700 Series Super Pump Series - Hayward
This manual contains information for the proper installation and operation of the Hayward Super Pump® 700 Series. IMPORTANT SAFETY INSTRUCTIONS Hayward Pool Products
Install Guide | IntelliFlo VSF Install Guide - Pentair
• These instructions contain information for a variety of pump models and therefore some instructions may not apply to a specific model. All models are intended for use in swimming …
POOL PUMP - Inyo Pools
Install, ground, bond, and wire motor in accordance with local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor …
CENTURY POOL & SPA MOTOR MANUAL - Electric Motor …
W. elcome to A.O. Smith’s line of Century®. Motors. This pocket manual is designed for one purpose — to make it simple for you to install, maintain and troubleshoot Century pool and spa …
Pool Pump Wiring Diagrams Full PDF - netsec.csuci.edu
Understanding pool pump wiring diagrams is essential for maintaining your pool equipment. While the process can seem daunting at first, with careful attention to detail and a methodical …
Heat Pump Installation, Maintenance and Service Manual
INTRODUCTION. Rheem Thermal Pool Heat Pumps are available in sizes from 9kW to 540kW nominal output. The units are most commonly manufactured as air-to-water design, in which it …
Wiring A Pool Pump Motor Diagram Copy - netsec.csuci.edu
wiring a pool pump motor, providing clear explanations, diagrams, and crucial safety precautions to help you get your pool sparkling again. We'll cover common motor types, interpreting wiring …
STA-RITE SUPERMAX VS VARIABLE SPEED PUMP - Pentair
Wiring Overview and Installation Control with External Control/Inputs Connecting to External Controls Using the Supplied Low Voltage Signal for ... models are intended for use in swimming pool applications. The pump will function correctly only if it is properly sized to the specific application and properly installed.
Super II™ Pump Series - Owner's Manual - Backyard & Pool …
supply. Provide a properly located outlet. It is required that licensed electricians do all electrical wiring. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or motor, disconnect motor wiring. WARNING – To reduce the risk of electric shock replace damaged cord ...
EMERGENCY SHUT-OFF / POWER DISCONNECT - Inyo Pools
inside edge of pool or spa, in line of sight from pool or spa. 3. Do not exceed the maximum ratings of individual components, wiring devices and current carrying capacity of conductors. 4. For grounding of the installation, refer to section 250 and 680 of the National Electrical Code. 5.
SELF-PRIMING POOL/SPA PUMP - Pioneer Distribution
DYNAPRO® Self-Priming Pool/Spa Pump Installation and sers Guide P/N S771 Rev. D 4/4/17 If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please contact:
TriStar® Pump Series - OWNER’S MANUAL - Pool Warehouse
damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to return back to the pool.
1.5HP 115V IN/ABOVE GROUND POOL PUMP 5280GPH
1.5HP 115V IN/ABOVE GROUND POOL PUMP 5280GPH SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, ... It is required that licensed electricians do all electrical wiring. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or
Mechanical Timing Controls For Two-Speed Pump …
pump application it will turn the pump ON and OFF. The T106M has an SPDT (single pole, double throw) mechanical switch. This timer is used to change the speed of the pump. The T106M can be wired so that the pump turns on at low speed (as shown in the wiring diagram below) or at high speed. The ON/OFF trippers are used to switch the speed of the ...
OWNER’S Manual - THERMEAU®
with an effective, state-of-the-art technology heat pump. In general, compared to other types of pool heaters, such as gas or oil-fired, the THERMEAU pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs to operate for a longer time to accomplish the desired results. Occasionally, it may be necessary to run the heat ...
SWIMMING POOL HEAT PUMP Installation & Instruction …
② The heat pump needs a water pump (Supplied by the user). Max. lift 30ft; ③ When the heat pump is running, there will be condensate water discharged from the bottom that must be properly managed and directed away from the heat pump. Please insert the
SMF PUMP OWNER’S MANUAL - Waterway Plastics
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. 1. Make sure all electrical breakers and switches are turned off before wiring motor. 2. Make sure that the wiring voltage matches the motor
HCP3000 Series Variable Speed Pump - Hayward
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1! WARNING - Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow instructions can cause severe injury and/or death. WARNING – This product should be installed and serviced only by a qualified professional. CAUTION – All electrical wiring MUST be in conformance with all …
LOAD CENTER AND POWER CENTER - Pentair
install a motorized two-port Pool Cleaner Valve at this line. The motorized valve will automatically open whenever the Control System activates the pool cleaner. If a booster pump pool cleaner is being used, plumb the booster pump so that its suction-side is connected to the pool return, after the heater, and as close to the ground as practical ...
STA-RITE MAX-E-PRO HIGH EFFICIENCY POOL AND SPA PUMP
BEFORE WORKING ON PUMP! Always disconnect power to the pool pump at the circuit breaker from the pump before servicing the pump. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock. THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE
BOOSTER PUMP - Pentair
This pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable
Heat Pump - Hayward
within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures. CAUTION - These heaters are intended for use with permanently-installed pools and may be used with hot tubs and spas if so marked.
WHISPERFLO - Pentair
electrical wiring installation wiring grounding bonding maintenance ... a person sits on a broken or uncovered pool drain) or hair entanglements. this pump produces high levels of suction and creates a . strong vacuum at the main drain at the bottom of the body . of water. this suction is so strong that it can trap adults
Polaris Booster Pump Installation Instructions - Pool …
The Polaris booster pump supplies high pressure water to the Polaris pool cleaner to optimize cleaner efficiency. The pump is not self-priming and should only be used when the pool filtration pump is on. Running the booster pump without the filtration pump will damage the booster pump. Improper operation of the booster pump will void the warranty.
Polaris Booster Pump Installation Instructions - Hydropool.com
manufactured by Polaris Pool Systems, Inc., 2620 Commerce Way, Vista, CA 92081-8438, USA. Polaris Pool Systems warrants the PB4-60 Booster Pump it manufactures, including all parts and components thereof, to be free of defects in material and workmanship.
Installation & Instruction Manual - Oasis Heat Pumps
3.5 Swimming Pool Heat Pumps Electrical Wiring 3.6 Initial Start-up of the Unit ... The schematic diagram is for reference only. Please check the water inlet/outlet label on the ... Location: Connect the unit in the pool pump discharge (return) line downstream of all filter and pool pumps, and upstream of any chlorinators, ozonators or chemical ...
Swimming Pool Heat Pump INSTALLATION AND USER …
2.Electric Wiring Diagram . Breaker/fuse (Customer prepare) Earthing Power Supply 230V/ 60Hz L1 L2 Breaker/fuse (Customer prepare) Earthing Power Supply 230V/ 60Hz L1 L2 Pump Heat Pump contactor Terminal Board Users'Electric Box. Note:The swimming pool heater must be electrically bonded. Outlet Inlet Bonding . Bonding
AUTOMATIC SAFETY POOL COVER INSTALLATION GUIDE
Wiring The Electrical Switch Connect the electric switch by wiring the neutral wire from the power supply, the white wire from the motor and one of the wires from the indicator light together using a wire nut. Note: Switch must be mounted in a position with a full view of the pool. Connect the ground wires from the power supply
TriStar® Pump Series - OWNER’S MANUAL - Pool Warehouse
damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to return back to the pool.
1.5 HP 5280 GPH CSA IN GROUND POOL PUMP
1.5 HP 5280 GPH CSA IN GROUND POOL PUMP SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. ... that licensed electricians do all electrical wiring. All electrical wiring MUST be in conformance with applicable local and national codes …
Pool Pump Wiring Schematic - goramblers.org
Pool Pump Wiring Schematic Handbook of Landscape Architectural Construction Jot D. Carpenter 1976 Boiling Nuclear Superheater (BONUS) Power Station 1962 Radiant heating, water heaters, ventilation, air conditioning, heat pumps, air cleaners James E. Brumbaugh 1983 Guide to Atomic Energy Literature for the Civilian Application
Swimming Pool Heat Pump INSTALLATION AND USER …
Similarly, you should not install automatic sprinkler near your pool heat pump. The device must be installed on a flat, firm and level surface. A concrete slab or equivalent is preferred. ... B.Check the electric wiring according to the electric wiring diagram; and grounding connection. C.Make sure that the main machine power switch is off
IntelliFlo Wiring Instructions - Hydropool.com
pump at the circuit breaker from the pump before servicing the pump. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock. Drive with a 3-Wire Harness Drive with a Field Wiring compartment FIELD WIRING COMPARTMENT CONNECTIONS L1 = HOT LEAD L2 = HOT LEAD GREEN SCREW = GROUND LEAD ...
EcoPump Owners Manual
NOTE: If the pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to re-open valves prior to operating. Note: See wiring diagram on side\rof pump for specific wiring instructions.
Pool Pro Ultra VS - Doheny
injury or death. this pump should be installed and serviced only by a qualified pool service professional. installers, pool operators and owners must read these warnings and all instructions in the owner’s manual before using this pump. these warnings and the owner’s manual must be left with the pool owner. do not permit children to use ...
LX820 EMERGENCY SHUT-OFF CONTROL SYSTEM - Pentair
Feb 5, 2024 · Pool Filter Pump Control It is possible to add a power relay so that the Pool Filter Pump will be inactivated by the emergency Shut-off Switch. Install model RLY-SC Relay Kit in the high voltage compartment of the LX-820 in accordance with instructions provided, and plug onto circuit board at POOL PUMP socket. For 3HP pump use 3HP Relay ...
48/56 FRAME EXECUTIVE, EX2, & VIPER PUMP …
incorrect wiring insure that wiring circuit and wiring diagram are the same. incorrect voltage incorre ct wiring pump binding motor binding check voltage, if incorrect, call an electrician. i ns ure th aw g d wiring diagram are the same. ta ke pr um , l o for signs of rubbing. if motor will not turn by itself see an authorized motor service ...
Super Pump Series - Horizon Commercial Pools
Super Pump® Series Owner’s Manual IMPORTANT SAFETY INSTRUCTIONS The Hayward Super Pump® is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Super Pump® is a self-
SWIMMING POOL HEAT PUMP UNIT - Water and Pool Systems
3.5 Swimming Pool Heat Pumps Electrical Wiring 3.6 Initial Start-up of the Unit ... The schematic diagram is for reference only . Please check the water inlet/outlet label on the ... Location: Connect the unit in the pool pump discharge (return) line downstream of all filter
OWNER'S MANUAL Pool Pro Ultra AG - Doheny
pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to service person, pool users or others ... All wiring (electrical) work must be carried out by licensed electricians and must be installed in accordance to the local codes. 6. The motor must be grounded. 33 72808:
Hayward Super Pump™ Series - Owner's Manual
Super Pump™ Pump Series _____ _____ _____ Page 4 of 15 WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation …
IntelliFlo Variable Speed Pump Installation and User's Guide
only by a qualified pool service professional. installers, pool operators and owners must read these warnings and all instructions in the owner’s manual before using this pump. these warnings and the owner’s manual must be left with the pool owner. do not permit children to use this product. risk of electrical shock. connect only to
Heat Pump Installation, Maintenance and Service Manual
27/5/2019 Heat Pump Installation, Maintenance and Service Manual This booklet is to be carefully read and instructions followed for efficient and trouble free operation of the
Typical Pool Plumbing Schematic - teipamecon.wordpress.com
tank filter control valve diagram typical inground pool pump filter piping diagram inground pool piping diagrams pool 2004 volvo s80. Local codes may require the pool piping system to be ... plumbing. the piping from the outlet of the pool heater to the pool or tub. to the wiring schematic in Figure 5 on page 8 for proper condensation. It is ...
HEAT PUMP POOL HEATERS - Aqua Comfort Solutions
Connect control wiring to either Pool/Spa connection at the bottom right of control board. 4. SEE: REMOTE CONTROLS THERMOSTATS AND CONTROLS WIRING DIAGRAM 1. Use copper conductors only 2. Connect field wiring in grounded rain tight conduit, per rating plate. 3. Connect bond wire to pool steel using # 8 solid copper wire or larger. 4.
Super Pump
%PDF-1.6 %öäüß 1 0 obj /Metadata 2 0 R /OCProperties /D /OFF [] /ON [3 0 R] /Order [[(SP REVB p1.ai) 3 0 R] [(SP REVB p2.ai) 4 0 R] [(SP REVB p4.ai) 5 0 R] 6 0 R] /RBGroups [] >> /OCGs [3 0 R 4 0 R 7 0 R 5 0 R 6 0 R] >> /Pages 8 0 R /Type /Catalog >> endobj 9 0 obj /CreationDate (D:20141212094709+11'00') /Creator (Adobe Illustrator CS6 \(Windows\)) …
VARIABLE SPEED POOL PUMP - m.media-amazon.com
Caution for Pump Installation: Ensure the pump is protected from moisture and potential flooding. It's recommended not to install the pump more than 3 meters above the water level to ensure optimal performance. Regardless of the pump's height above the water and the capacity of the chosen model, be aware that priming can take several minutes.
Heat Pump - Hayward
within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures. CAUTION - These heaters are intended for use with permanently-installed pools and may be used with hot tubs and spas if so marked.
Power-Flo LX™ / Power-Flo II™ Pump Series
The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to right). Self-priming Power-Flo II™ pumps may be installed up to four (4) feet above the pool water line. Install pump on a firm, level base or pad to meet all local and national codes. The field supplied base or pad must be level and vibration-free.
Hayward HeatPro™ - Owners Operation & Parts Manual
Page 4 of 24 HEATPRO HEAT PUMP HP13023772 Rev: B USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com 6. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir pool/spa water before entering the pool/spa to
Swimming Pool Heat Pump INSTALLATION AND USER …
A circuit breaker must be installed close to the heat pump, in an accessible location. Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump. If your heat pump has a pool pump control option, …
Pressure Cleaner Booster Pump - Pool Cleaning Parts
Polaris® PB4-60 Booster Pump | Installation and Operation Manual ENGLISH Page 5 1.2 Pool Pump Suction Entrapment Prevention Guidelines At least three (3) feet Suction Outlet (Main Drain) Suction Outlet (Main Drain) No valves between Tee and Main Drains Listed/certified to latest published version of ANSI/ASME A112.19.8 - 2007 or its successor,
Pump Motors Tro u b l e s h o o t i n g - Inyo Pools
34 Pump Motors A.O.Smith • Make sure there are no obstructions preventing the proper operation of the rotating governor. Check wiring and make sure none of the leads are in the area of the governor where they can be cut or interfere with the governor. Check governor for proper operation and make sure flipper moves freely.
CENTURY POOL & SPA MOTOR MANUAL - m.media …
e n t u r y pool and spa pump motors are tailored for demanding pool loads and environments. Check these outstanding feature s : 1 . Full-rated 56-Frame diameter gives greater thermal c a p a c i t y , better durability with industrial quality constru c t i o n . CENTURION® DESIGN FEATURES FLEX-48™ POOL AND SPA MOTORS
ABOVE GROUND PUMP POOL 1.5HP 2 SPEED
the pool water be maintained. This is the pH of your pool with pH 7.0 being neutral. Readings above 7.0 are alkaline and below are acid. A desirable range is 7.2 – 7.4. PUMP MAINTENANCE 1.Motors are self-lubricating – no lubrication required. 2.Clean hair & lint strainer if you have a strainer body pump.
Motor Control Board Wiring and Installation Instructions
Make/ reak: An option for pool automation utilizing the white and black colored wires. This option is compatible with the following systems: Pentair Intellicenter panels: onnect to pool cover expansion card. (Pool cover 1 or Pool cover 2) Hayward panels: onnect to “EXTNL INPUT” port.
SUPERMAX HIGH PERFORMANCE PUMP
SUPERMAX ® i erformanc ti i iii Warning Page P/N 352557 Rev. C 7/18 IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS For Installation of Electrical Controls at Equipment Pad (ON/OFF