Wiring a Pool Pump Motor Diagram: A Comprehensive Guide
Introduction:
So, your pool pump motor has given up the ghost, or perhaps you're tackling a new installation. Either way, staring at a tangle of wires and a cryptic motor diagram can be daunting. This comprehensive guide will walk you through the process of wiring a pool pump motor, providing clear explanations, diagrams, and crucial safety precautions to help you get your pool sparkling again. We'll cover common motor types, interpreting wiring diagrams, troubleshooting common issues, and ensuring a safe and efficient installation. By the end, you'll confidently understand how to wire your pool pump motor correctly.
Understanding Your Pool Pump Motor
Before diving into the wiring, it's vital to understand the type of motor you're working with. Pool pumps primarily use single-phase or three-phase motors.
Single-Phase Motors:
These are the most common type found in residential pools. They operate on standard household power (typically 110V or 220V depending on your region). Wiring diagrams for single-phase motors are generally simpler.
Three-Phase Motors:
These are more powerful and are usually found in larger commercial pools or those with high-volume filtration systems. Wiring three-phase motors requires a more complex understanding of electrical systems and should ideally be handled by a qualified electrician.
Identifying Your Motor Type and Voltage:
Check the motor's nameplate. This plate, usually attached to the motor housing, provides essential information including voltage, amperage, horsepower, and sometimes a basic wiring diagram. This is your first and most important step. Incorrect voltage can seriously damage your motor.
Deciphering the Wiring Diagram
The wiring diagram on your motor’s nameplate or in your pump's instruction manual is crucial. These diagrams use standardized symbols to represent wires and connections.
Common Symbols:
L1, L2 (Single-Phase): These represent the incoming power lines (hot wires).
L1, L2, L3 (Three-Phase): These represent the three incoming power lines (hot wires).
N (Neutral): The neutral wire completes the circuit.
GND (Ground): This crucial wire provides a safety path for electrical current to ground, preventing shocks.
C (Capacitor): Some single-phase motors use a capacitor to start the motor. The diagram will indicate capacitor connections.
Terminal Numbers: Numbers on the diagram correspond to terminal screws on your motor.
Step-by-Step Guide to Interpreting Diagrams:
1. Identify your motor type: Single-phase or three-phase? This dictates which part of the diagram to focus on.
2. Locate the terminal numbers: These correspond to the physical terminals on the motor.
3. Follow the lines: Trace the lines from the power source (L1, L2, L3, N) to the appropriate terminal numbers.
4. Note any capacitors: Identify the capacitor's connection points and ensure it's correctly wired.
Wiring a Single-Phase Pool Pump Motor (Example)
Let's assume a simple single-phase motor. The diagram may show L1 connected to terminal 1, L2 to terminal 3, and a capacitor connected between terminal 2 and 3, and N connected to terminal 4. This is a common, but not universal, example. Always follow your specific diagram.
Step-by-Step Wiring:
1. Disconnect power: Absolutely crucial before working with any electrical equipment. Turn off the breaker controlling the pool pump circuit.
2. Connect the ground wire: Securely attach the ground wire (typically green or bare copper) to the motor's ground terminal.
3. Connect the neutral wire (if applicable): Connect the neutral wire (white) to the designated neutral terminal.
4. Connect the hot wires: Connect the hot wires (black and red) to the terminals specified on the diagram, ensuring correct connections with the capacitor if one is used.
5. Double-check your connections: Verify each connection before re-energizing the circuit.
6. Restore power: Turn the breaker back on.
Safety Precautions:
Always disconnect power before starting any wiring work.
Use appropriate safety equipment: Rubber gloves and safety glasses are highly recommended.
If you're not comfortable working with electricity, consult a qualified electrician.
Never work with wet hands or in wet conditions.
Ensure proper grounding to prevent electrical shocks.
Troubleshooting Common Issues
If your pump doesn't work after wiring, check these points:
Verify power: Ensure power is reaching the breaker and the pump's power cord is properly connected.
Check connections: Double and triple-check all wiring connections for tightness and correctness.
Inspect the capacitor: If your motor uses a capacitor, check it for any signs of damage or bulging.
Test the motor: Use a multimeter to test the motor's windings for continuity.
Conclusion:
Wiring a pool pump motor can seem intimidating, but with a clear understanding of your motor type, careful interpretation of the wiring diagram, and a methodical approach, the task becomes manageable. Remember to prioritize safety above all else and consult a professional if you have any doubts. A properly wired pool pump ensures efficient filtration and a clean, healthy swimming environment.
FAQs
1. Can I use a different type of wire than what's specified in the instructions? No, always use the wire gauge and type specified in the motor's instructions or on the wiring diagram. Using incorrect wire can lead to overheating, fire hazards, and motor damage.
2. What if my wiring diagram is missing or damaged? Contact the manufacturer of your pool pump for a replacement diagram. They should be able to provide one.
3. My motor is making strange noises. What could be the issue? This could indicate a mechanical problem with the motor itself, not necessarily an electrical one. Consult a pool pump repair professional.
4. How often should I inspect my pool pump wiring? While not requiring frequent checks, a visual inspection once or twice a year can help identify any loose connections or signs of damage before they cause a problem.
5. Is it possible to wire a three-phase motor myself if I have experience with electricity? While technically possible with adequate knowledge and experience, wiring a three-phase motor is significantly more complex and risky than single-phase. It's generally recommended to seek professional assistance for three-phase motor installations.
CENTURY POOL & SPA MOTOR MANUAL - Electric Motor …
CENTURY®. POOL & SPA MOTOR MANUAL. 1. W. elcome to A.O. Smith’s line of Century®. Motors. This pocket manual is designed for one purpose — to make it simple for you to install, …
POOL PUMP MOTORS - Nidec
• Follow the motor connection diagram on the motor nameplate. • Make sure the motor is properly grounded and complies with local and national electrical codes. KEY TAKEAWAY: A pool …
Wiring Diagram
Step 9 Finally, prime the pump and turn on the power at the breaker. For a complete Step by Step video on how to wire your PureLine Motor for 230V check out this video: …
RX Clear ® Mighty Niagara In-ground pump
Install in-ground pool pump, wire motor in accordance with local and national electrical code requirements. Permently ground motor, by connecting ground wire to grounded bolt. Use size …
HAYWARD SELF-PRIMING SUPER PUMP INSTALLATION AND …
Insure electrical supply agrees with motor voltage, phase and cycle, and that wire size is adequate for the HP/KW rating and distance from power source. Motor must always be …
OWNER’S MANUAL - SPECK Pumps
Motor name plate has voltage, phase, ampere draw and other motor information as well as wiring connection instructions. BONDING: As required by National Electrical Code Article 680-26, the …
A3101 E0301 A3100 - Wiring and Installation - Latham Pool
(5VDC) options are all available as indicated on pages 3,6, & 7 wiring diagram. Directional signals are required for proper controller operation of sensing and motor controls.
PowerFlo LX / PowerFlo II / EP Pump Series - Hayward
Pump Series Owner’s Manual INSTALLATION, OPERATION, & PARTS IMPORTANT SAFETY INSTRUCTIONS Hayward Pool Products 620 Division Street, Elizabeth, NJ 07207 Phone: …
tm Wiring Diagram EXPLODED VIEW - ecopoolpumps.com
Wiring Diagram. WARNING: Before installing this instructions accompanying this pump. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. …
Install Guide | IntelliFlo VSF Install Guide - Pentair
This guide provides installation and operation instructions for this pump. Consult Pentair with any questions regarding this equipment. Attention Installer: This guide contains important …
Power-Flo LX / Power-Flo II Pump Series - Owner's Manual
Install, ground, bond, and wire motor according to local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or …
48/56 FRAME EXECUTIVE, EX2, & VIPER PUMP INSTRUCTIONS …
MOTOR WIRING. Before working on any electrical connections be sure that the power is turned of. All wiring must conform to local, state and/or national codes. All wiring must conform to …
Super Pump Series - Hayward
bonding wire to the pressure wire connector provided on the pump housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas …
SuperFlo Manual (DOE Compliant) - English - Pentair
Become familiar with the wiring diagram and electrical specifications of your particular pump motor. This information is provided on the motor nameplate label found on the side of the …
Challenger High Pressure Pool and Spa Pump - Pentair
Your centrifugal pump is driven by an electric motor. The motor is directly attached to the pump impeller. As the electric motor turns, it causes the impeller to turn and this causes the water to …
Hayward Super Pump™ Series - Owner's Manual - Pooltek
Install, ground, bond, and wire motor in accordance with local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor …
Super Pump 700 Series Super Pump Series - Hayward
This manual contains information for the proper installation and operation of the Hayward Super Pump® 700 Series. IMPORTANT SAFETY INSTRUCTIONS Hayward Pool Products
CHAMPION PUMP OWNER’S MANUAL - Waterway Plastics
Permanently ground the motor using the internal, green ground terminal located on the inside of the motor canopy or access plate (Figure 1). Use the correct wire size and type specified by …
Pool Pump Wiring Schematic Copy - netsec.csuci.edu
Understanding your pool pump's wiring schematic is crucial for efficient operation and safety. By familiarizing yourself with the basic symbols, common configurations, and troubleshooting …
Pump Motors for Swimming Pools, Spas & Jetted Tubs - Pool …
Before using the Pool & Spa Motor Replacement Guide, you will need to know the horsepower (1), the service factor (2) of the original motor, and the name and/or the manufacturer of the …
CENTURY POOL & SPA MOTOR MANUAL - Water Heater Timer
e n t u r y pool and spa pump motors are tailored for demanding pool loads and environments. Check these outstanding feature s : 1 . Full-rated 56-Frame diameter gives greater thermal c a p a c i t y , better durability with industrial quality constru c t i o n . CENTURION® DESIGN FEATURES FLEX-48™ POOL AND SPA MOTORS
CENTURY POOL & SPA MOTOR MANUAL - m.media …
e n t u r y pool and spa pump motors are tailored for demanding pool loads and environments. Check these outstanding feature s : 1 . Full-rated 56-Frame diameter gives greater thermal c a p a c i t y , better durability with industrial quality constru c t i o n . CENTURION® DESIGN FEATURES FLEX-48™ POOL AND SPA MOTORS
2HP INGROUND POOL PUMP 5850GPH DUAL VOLTAGE …
2hp inground pool pump 5850gph dual voltage motor save this manual: keep this manual for safety warnings, precautions, assembly, operating, inspection, maintenance and cleaning procedures. write the product’s serial number on the back of the manual near the assembly diagram (or month and year of purchase if product has no number).
PERMANENTLY INSTALLED SWIMMING POOLS - nyeia.com
1) Pool Pump Receptacle (Outlet) and Wiring Method a. Swimming pool pump motor receptacle must be located at least 6’ from the inside pool wall, must be grounded, and Ground Fault Circuit Interrupter (GFCI) protected. b. Receptacle must have an extra-duty, in-use, weatherproof cover that can be closed when the cord is plugged in.
1.5HP 115V IN/ABOVE GROUND POOL PUMP 5280GPH
1.5hp 115v in/above ground pool pump 5280gph save this manual: keep this manual for safety warnings, precautions, assembly, ... serial number on the back of the manual near the assembly diagram (or month and year of purchase if product has no number). owner’s manual and safety instructions ... before working on pump or motor, disconnect motor ...
OWNER’S MANUAL - SPECK Pumps
680-26, the pump motor must be electrically bonded to the spa structure (reinforced bars, etc.) by a solid copper conductor not smaller than #8 AWG (8.4 mm2) wire via the external copper bonding lug on the pump motor. GROUNDING: Permanently ground the pump motor using a conductor of appropriate size. Connect to the #10 green
AUTOMATIC SAFETY POOL COVER INSTALLATION GUIDE
Center the motor end and non-motor end in the housing front to back. Anchor the non-motor and motor end feet into the housing using as many anchor points as possible. 16 On the motor and non-motor side, use a 3/16” bit and drill through the cross braces. To secure, use the half inch screws (28) and nylock nuts (29)
IS3202VSP2B Rev-A 1.85 THP VS Pump Family - Hayward
Hayward Pool Products 620 Division St, Elizabeth, NJ 07207 Phone: (908) 355-7995 www.hayward.com 1.85 THP VS Pump Family Owner’s Manual 1.85 THP Variable Speed Pump Family Hayward’s 1.85 THP variable speed pump family delivers incredible energy savings via its advanced hydraulic design combined with a totally enclosed, permanent magnet motor.
PowerFlo Matrix Pump - Hayward
f the pool/spa ve. , dirt, hair, pap spected frequ r not securely tioned so as to t permit childre system, pump r hazardous pr t during pump housing and c ere personal in off position an e set in a posit pump is runni f valve until a s d result in viole th strainer cove osition. Do no ing. Do not ope er body. Neve air. Purging th nearby. Use on ...
Super II™ Pump Series - Owner's Manual - Backyard & Pool …
supply. Provide a properly located outlet. It is required that licensed electricians do all electrical wiring. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or motor, disconnect motor wiring. WARNING – To reduce the risk of electric shock replace damaged cord ...
Prime Plus Pump - Inyo Pools
plumbing a pool pump. Pool Plumbing Best Practices It is best to use larger plumbing on the suction side of the pump, as this will allow the pump to prime easier and put less stress on the pump resulting in longer pump life. 2” or 2.5” plumbing going into the suction port of the pump is recommended. Example 1 - Use 2.5” plumbing on the ...
MaxFlo VS (SP23520VSP) - Hayward
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 5 of 36 MaxFlo VS 500 Pump IS23520VSP Rev-C WARNING – Pool and spa components (seals, gaskets, etc.) have a finite life. All components should be inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or
CHAMPION PUMP OWNER’S MANUAL - Waterway Plastics
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. 1. Make sure all electrical breakers and switches are turned off before wiring motor. 2. Make sure that the wiring voltage matches the motor
MAX-E-PRO SERIES PUMP REPLACEMENT PARTS - Pentair
22 C104-79P Base w/ Motor Pad (3 HP only) 23 C35-43 Motor Pad 23 C35-44 Motor Pad (3 HP only) 24 U30-74SS 3/8-16 x 1 in. Hex Hd. Screw MAX-E-PRO® SERIES PUMP (CONT’D) REPLACEMENT PARTS Replacement parts pricing on page 635. Product on pages 194–197. Model No. HP Motor No. (Item No. 1) Impeller (Item No. 10) Diffuser (Item No. 11)
Ultra-Efficient Variable Speed Pump - Installation and
Proper pool chemistry must be maintained at all times. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new requirements for owners and …
Replacement Parts Parts Diagram - Proline Distributors
Super Pump ™ Series ... 14 MOTOR MOUNTING PLATE 1 SPX1600F5 SPX1600F5 SPX1600F5 SPX1600F5 SPX1600F5 SPX1600F5 15 HOUSING CAP SCREW 4 SPX1600Z4 SPX1600Z4 SPX1600Z4 SPX1600Z4 SPX1600Z4 SPX1600Z4 ... Hayward Pool Products Created Date: 7/16/2012 3:18:36 PM ...
TriStar® Pump Series - OWNER’S MANUAL
working on pump or motor, turn off power supply to the pump. WARNING – To reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse from lawn mowers, hedge trimmers and other equipment. WARNING – It is recommended to install a Ground Fault Circuit Interrupter (GFCI) in the circuit, however, all
Pool & Spa Motors - Nidec
Pool & Spa Motors Pool & Spa Motors Frame Size: NEMA ®† 48 and 56 Horsepower: 1/2 through 60 HP Phase: Single & Three Phase RPM: 60 Cycle - 3450 & 3450/1725 50 Cycle - 2850 & 2850/1425 Speeds: Single and Two Speed (Hard & Soft Start) and Variable Speed Voltage: • …
VARIABLE SPEED POOL PUMP - m.media-amazon.com
The pump must not be used when people are in the water. Caution for Pump Installation: Ensure the pump is protected from moisture and potential flooding. It's recommended not to install the pump more than 3 meters above the water level to ensure optimal performance.
OWNER’S MANUAL - Waterway Plastics
1. Drain pump by removing drain plug(s) and store in strainer basket. 2. Disconnect electrical wires and protect pump assembly from the elements by covering. Or, you may choose to disconnect electrical wires and pipe connections, and store pump in a dry, well-ventilated room. NOTE: Before reactivating pump, relubricate o-rings and thoroughly
WHISPERFLO® VS WHISPERFLO® VST - Pentair
power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using. This pump is for use with permanent swimming pools
BOOSTER PUMP - Pentair
accessible wire connector on the motor to all metal parts of the swimming pool, spa or hot tub structure and to all electrical equipment, metal conduit and metal piping within 5 ft. (1.5 m) of the inside walls of the swimming pool, spa or hot tub when the motor is installed within 5 ft.
Model T104P201 with Plastic enclosure Model T104R201 with …
gas-fired pool heater 15-20 minutes before turning off filter pump. This eliminates knocking due to overheated water, reduces scale and lime, and extends service life of heater Heater protection circuit: 10A 240V max. WG1573 clock motor/ 156T1978A Tripper / 9-3/8” H x 5-1/2” W x 3-5/8” D/ ½” and ¾” KO on back and side
Astral eVoP320n600 Pump Technical Manual_2012 - Rainbow …
Inst.300 Viron EVO Pool & Spa Pump V01_12 4 GENERAL The Viron EVO Pool Pump is a unique variable-speed permanent magnet DC motor combined with an energy efficient pump wet end. When installed and plumbed correctly, the Viron EVO will significantly reduce operating costs, lower noise levels and reduce greenhouse emissions.
1.5 HP 5280 GPH CSA IN GROUND POOL PUMP
1.5 HP 5280 GPH CSA IN GROUND POOL PUMP SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, ... SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER). OWNER’S MANUAL AND SAFETY INSTRUCTIONS ...
Save-T 3 Automatic Pool Cover Owner’s Manual - Cover-Pools
If your pool has a latching strap, immediately latch the leading edge once the pool has been completely covered (see “Latching Procedure” below). Place the cover pump on the cover at this time (see “Placing the Pump on the Cover” on page 9.) Keep the pump on the cover whenever the pool is covered. Uncovering the Pool
Hayward Variable Speed Pump
install pump and filter in a damp or nonventilated location. - • Allow adequate access for servicing pump. Keep motor clean. Pump motors require free circulation of air for cooling. • It is recommended that a minimum length of straight piping (shown as “L” in below diagram), equivalent to 5 times the pipe diameter, be used between the pump
Installation and Operation Manual FloPro Series Pumps - Inyo …
1.2 Pool Pump Suction Entrapment Prevention Guidelines WARNING Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines provide information for pump installation that minimizes the risk of injury to
SUPERFLO PUMP REPLACEMENT PARTS - Pentair
PUMP PARTS - INGROUND Replacement parts pricing on page 635. Product on pages 182–183. SUPERFLO® PUMP REPLACEMENT PARTS Item Part No. Description SINGLE SPEED SUPERFLO MOTORS 1 355018S 1/2 HP Motor SQFL, 1 Speed, 1 phase, 115/208-230, 60 Hz, almond 1 355018S 3/4 HP Motor SQFL, 1 Speed, 1 phase, 115/208-230, 60 Hz, almond 1 …
ELECTRICAL WIRING REQUIREMENTS FOR SWIMMING …
1) Pool Pump Receptacle (Outlet) and Wiring Method A. If a pump motor receptacle is located between 6’ – 10’ from the inside pool wall, the receptacle must be a single twist-lock outlet, grounded, and GFCI protected. Maximum flexible cord length for pump is 3 Ft. B. Receptacle must have a weatherproof cover that can be closed when the cord is
Pentair Dynamo Pump Owner's Manual - RoyalSwimmingPools
Your centrifugal pump is driven by an electric motor. The motor is directly attached to the pump impeller. As the electric motor turns, it causes the impeller to turn and this causes the water to flow. The water flows into the hair and lint pot inlet and …
OWNER’S MANUAL - SPECK Pumps
680-22, the pump motor must be electrically bonded to the pool structure (reinforced bars, etc.) by a solid copper conductor not smaller than #8 AWG (8.4 mm2) wire via the external copper bonding lug on the pump motor. GROUNDING: Permanently ground the pump motor using a conductor of appropriate size. Connect to the #10
Pentair SuperFlo Pump Owner's Manual
A clearly labeled emergency shut-off switch for the pool pump and spa jet pump must be in an easily accessible, obvious place near the pool or spa. Make sure bathers know where it is and how to use it in case of emergency. Pentair Water Pool and Spa® PUMP WARNING AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps)
Pressure Cleaner Booster Pump - Pool Cleaning Parts
Polaris® PB4-60 Booster Pump | Installation and Operation Manual ENGLISH Page 5 1.2 Pool Pump Suction Entrapment Prevention Guidelines At least three (3) feet Suction Outlet (Main Drain) Suction Outlet (Main Drain) No valves between Tee and Main Drains Listed/certified to latest published version of ANSI/ASME A112.19.8 - 2007 or its successor,
Electrical WIRING REQUIREMENTS FOR SWIMMING POOLS
1) Pool Pump Receptacle (Outlet) and Wiring Methods a. For permanently intended pump motor receptacle shall located between 6’ to 10’ feet from the inside pool wall, the receptacle must be a single twist-lock outlet, and always a GFCI (Ground Fault) protected. (see diagram 1a & 1d) b.
POOL PUMP MOTORS - Nidec
motor voltage. Review the wiring diagram on the motor label to be sure that your power leads and ground wire are correctly connected. In addition to following the manufacturer’s instructions, there are other things to always keep in mind when installing a pool pump motor: • Make sure your motor shaft turns freely by hand before starting the ...
WHISPERFLO PUMP PUMP PARTS - INGROUND …
Dec 17, 1999 · 355001S Motor for Pump 011021 355002S Motor for Pump 340061 400013Z Motor End Cap and Screw 350199 Seal Plate Kit (ozone/salt resistant) Replacement parts pricing on page 635. Product on pages 172–173. 1 Used on pumps manufactured before 6-94. 2 Used on pumps manufactured after 6-94. 3 Energy efficient single phase.
DUAL SPEED POOL PUMP
WIRING For Single Speed Pumps If the pump comes with a power cord, no wiring is needed. If not, wire the pump as below: 115 How to wire 230V • Make sure the switch is at the 230V side. • Ground wire connects to the ground terminal. • Hot wire connects to terminal 1 or 3; a neutral wire connects to terminal 3 or 1. Either hot wire or
STA-RITE SUPERMAX HIGH PERFORMANCE PUMP - Swim …
BEFOREWORKINGONPUMP!Alwaysdisconnect power to the pool pump at the circuit breaker from the pump before servicing the pump. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock. THEUSEOFUNAPPROVEDCOVERSORALLOWINGUSEOFTHE
BEFORE USING THE SPECK PUMP - poolinspections.com
Article 690-22, the pump motor must be electrically bonded to the pool structure (reinforced bars, etc.) by a solid copper conductor not smaller than #8 AWG via the external copper bonding lug on the pump motor. GROUNDING: Permanently ground the pump motor using a conductor of appropriate size. Connect to the #10 green headed ground screw provided
OWNER’S MANUAL Centrifugal Pumps - Poolweb
should be clockwise when viewed from the motor end. If not: • Turn pump OFF and disconnect from power source. • For three-phase motors, reverse any two leads to motor starter. • For single phase motors, re-connect according to wiring diagram on motor. Priming the Pump NOTICE: NEVER run pump dry. To run pump dry may damage seals. To Prime: 1.
WARNING - Cover-Pools
MOTOR POOL COVER HOUSING HYDRAULIC MOTOR END HYD PUMP UNIT CONDUIT FOR HYDRAULIC HOSE WITH SWEEPING BENDS LARGE SWEEPING BENDS Conduit to HYD pump J-box with 2 identified wires and 1 ground Conduit With (3) 12 AWG (min) Identified Wires plus one ground Conduit with (4) 18 AWG (min) Identified Wires for CoverLink Wired Control …
PE Series CENTRIFUGAL PUMPS - My Pool
Pool fittings must conform to International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use only non-entrapping suction fitting or double suction. TABLE I - RECOMMENDED FUSING AND WIRING DATA Serv. to Motor - Dist. in Ft. (M) Motor Branch Fuse Max Load Voltage/ 0-100' 101-200' 201-300'
Hayward/Summit Heat Pump
When the heat pump satisfies the thermostat and shuts off, the time delay will not allow . the heat pump to restart for 3 -5 minutes. The thermostat will turn the heat pump on and off . as needed to keep the pool at the desired temperature. Note: Heat pumps will …
Pantera Pool Pumps - Pentair
The Pantera range of pool pumps have been specifically designed to incorporate features that will provide reliable and efficient pump operation. The new technology wet end design integrates a unique moulded endshield cover and lip seal, protecting the motor from water damage making this range ideal for in-ground or above ground swimming pools.
ELECTRICAL WIRING REQUIREMENTS FOR SWIMMING …
1) Pool Pump Receptacle (Outlet) and Wiring Method A. If a pump motor receptacle is located between 6’ – 10’ from the inside pool wall, the receptacle must be a single twist-lock outlet, grounded, and GFCI protected. Maximum flexible cord length for pump is 3 Ft. B. Receptacle must have a weatherproof cover that can be closed when the cord is
INSTALLATION & OPERATING INSTRUCTIONS - Gecko
piping within 5 feet (1.5m) of the inside walls of the swimming pool, spa, or hot tub, when the motor is installed within 5 feet of the inside walls of the swimming pool, spa, or hot tub. note: for electrical connections, see wiring diagram on motor rating plate. general your aqua-flo pump has been quality built and engineered to give maximum
MaxFlo XL Pump Series - Hayward
MaxFlo XL is an ideal choice for both new construction or as a replacement pump. Hayward Pool Products 620 Division Street, Elizabeth, NJ 07207 Phone: (908) 355-7995 www.hayward.com ... Removing the Motor Assembly 10 7.2. Removing the Impeller 10 7.3. Removing the Ceramic Seat 10 7.4. Seal Installation 11 ... Parts Diagram 13 8.2. Parts Listing ...
Marathon Motor Wiring Diagrams Cat # Model
Marathon Motor Wiring Diagrams Cat # Model # Connection Diagram # PDF File E205 254TTFNA6026 A-EE7308 EE7308.pdf E206 256TTFNA6026 A-EE7308K EE7308K.pdf E207 284TTFNA6026 A-EE7308 EE7308.pdf E208 286TTFNA6026 A-EE7308 EE7308.pdf E209 324TTFS6026 A-EE7308 EE7308.pdf E210 326TTFS6026 A-EE7308 EE7308.pdf E211 …
SWIMMING POOL HEAT PUMP Manual - images.thdstatic.com
SWIMMING POOL HEAT PUMP Manual 1. Introduction The pool heat pump is a self-contained unit designed specifically for pool heating. Each component has been selected with care to achieve a high-quality product in an effort to exceed all industry standards. All pool heat pumps have an electronic board with service analyzer, a titanium heat